Wound string filter cartridges FKW
With wound filter cartridges, a yarn is wound around a support core. The yarn and support core are available in different materials.
Applications
Water treatment, seawater desalination, condensate treatment, process water, photographic chemicals, film development, edible oils, solvents, galvanic baths, greases, acids, alkalis, chemical processes.
Codierung | ||||
---|---|---|---|---|
Kerzentyp | Wickelmaterial | Stützkern | Länge | Feinheit |
FKW | 10 | P | P | 25 |
Technische Daten | |
---|---|
Längen | 5" | 9 ¾" | 10" | 19 ½" | 20" | 29 ¼" | 30" | 39" | 40" |
Durchmesser | AD: 62 mm | ID: 28 mm |
Filterfeinheit (Mikron nominal): | 0,5 | 1 | 3 | 5 | 10 | 25 | 50 | 75 | 100 | 150 | 200 |
Wickelmaterial: | P = Polypropylen | W = Polypropylen, gewaschen H = Glasfaser I B = Baumwolle PE = PolyesterI | N = Polyamid |
Material Stützkern: | P = Polypropylen | S = Edelstahl |
Max. Differenzdruck: | 2,5 bar bei 30°C |
Anfangsdifferenzdruck: | 0,1 bar |
Max. Betriebstemperatur: | 80°C bei Polypropylen | 135°C bei Polyamid 150°C bei Polyester | 150°C bei Baumwolle 400°C bei Glasfaser | 400°C bei Edelstahl |